Advertisement
Other Analyzers

Vacuum Process Diagnostic

August 18, 2014 8:49 am | Hiden Analytical, Inc. | Product Releases | Comments

The Hiden HMT residual gas analyzer (RGA) is conceived to offer a single partial pressure gauge to operate through the full vacuum spectrum from ultra-high vacuum (UHV) through to millitorr to provide process gas trend analysis, vacuum background diagnostics and leak detection.

LISTED UNDER: ANALYSIS INSTRUMENTS | Gas Analyzers | SPECTROMETRY AND SPECTROSCOPY

Thermogravimetric Analyzer

August 6, 2014 11:11 am | Product Releases | Comments

Mettler Toledo has introduced the TGA/DSC 2 featuring the XP micro- and XPU ultra-microbalances. The thermogravimetric analyzer can measure up to 50 million resolution points continuously down to 0.1 µg for a 5-g sample weight. Since a manual weight range change isn’t required when switching between small and large sample sizes, a variety of sample types can be measured in succession without user intervention.

LISTED UNDER: ANALYSIS INSTRUMENTS | Other Analyzers | Analytical Instrumentation

Thermomechanical Analyzers

July 15, 2014 10:28 am | Product Releases | Comments

Mettler Toledo has introduced a new line of thermomechanical analyzers, providing nanometer-resolution length measurements over a wide temperature range. The TMA/SDTA 1 features sample supports and probes that are easy to handle, and intelligent features with One Click operation, ensuring workflows are ergonomic and efficient.

LISTED UNDER: ANALYSIS INSTRUMENTS | Other Analyzers | Analytical Instrumentation
Advertisement

Differential Scanning Calorimeter

July 7, 2014 3:32 pm | Product Releases | Comments

Mettler Toledo has introduced the new DSC 2 with the new FRS 6 sensor, delivering better durability and reproducibility of results. The indium height to width ratio is improved to 19.5 mW/C and a now unprecedented 120 mW/C when applying data optimization.

LISTED UNDER: Analytical Instrumentation

Ammonia Analyzer

June 9, 2014 9:50 am | Product Releases | Comments

JM Science has introduced the AT-2000 ammonia analyzer based on coulometric titration technology. It can measure ammonium-nitrogen rapidly, accurately and easily without any specific skill by the end-user. The meter has a wide measurement range from low to high end with accurate measurement and is not interfered by turbidity or color of the sample.

LISTED UNDER: Analytical Instrumentation | Chemical Analyzers

Chemical Oxygen Demand Analyzer

April 23, 2014 9:15 am | Product Releases | Comments

In environment chemistry, the chemical oxygen demand (COD) test is commonly used to indirectly measure the amount of organic compounds in water. JM Science has introduced the Model HC-607 quick COD analyzer that provides fast, accurate analyses and is easy to use with coulometric titration.

LISTED UNDER: Chemical Analyzers

Coulometric Titration for Ammonium-nitrogen

February 12, 2014 11:16 am | Product Releases | Comments

JM Science has announced its AT-2000 ammonia analyzer, based on coulometric titration technology. It can measure ammonium-nitrogen rapidly, accurately and easily without skill by the end-user. The analyzer has a wide measurement range from low to high end with accurate measurement and is not interfered by turbidity or color of the sample.

LISTED UNDER: Analytical Instrumentation | Chemical Analyzers

CHN Analyzer for CROs and Service Labs

February 12, 2014 10:59 am | Product Releases | Comments

Exter Analytical Inc. has introduced the Model 440 CHN analyzer, which accurately analyzes a wide range of samples quickly, easily and reliably. Operating across a wide linear range, the Model 440 is capable of routinely determining percentage carbon, hydrogen and nitrogen levels in most sample types including organic compounds, pharmaceuticals, petrochemicals, polymers, refractory, environmental or natural materials.

LISTED UNDER: Carbon Analyzers | Hydrogen Analyzers | Nitrogen Analyzers
Advertisement

Compact Mass Spectrometer

February 4, 2014 4:31 pm | Product Releases | Comments

Advion Inc. has released the expression S, its latest compact mass spectrometer. The spectrometer's new enhancements include polarity switching during a single analysis to ensure detection of the greatest range of compounds and fast mass scanning of 10,000 u/sec for compatibility with UPLC, SFC and where multiple compounds must be monitored simultaneously with SIM, as well as higher flow rates of 1 to 2 mL/min for simpler interfacing with standard chromatographic conditions.

LISTED UNDER: Analytical Instrumentation | Other Mass | Spectrometers

Automatic Vapor Pressure Tester

February 4, 2014 4:22 pm | Ametek Process Instruments | Product Releases | Comments

AMETEK Petrolab has introduced the Grabner Instruments MINIVAP VPXpert-L, an automatic analyzer that accurately tests fuels and chemicals down to 0.1 kPa vapor pressure in temperature range from 0 to 120 C. The analyzer measures gasoline, jet fuels, solvents and chemicals, as well as food, flavor and fragrance products with high precision.

LISTED UNDER: Analytical Instrumentation | Automation Equipment

Second-generation AFM-based IR Spectroscopy Platform

February 4, 2014 4:17 pm | Product Releases | Comments

Anasys Instruments has introduced the nanoIR2, a second-generation AFM-based infrared (AFM-IR) spectroscopy platform. A key breakthrough is the ability of the nanoIR2 to operate with top-side illumination, eliminating the need to prepare samples on a ZnSe prism and enabling measurements on a much more diverse set of samples.

LISTED UNDER: Analytical Instrumentation | Atomic Force | Microscopes, Optics, Image Analysis, Lasers, Cameras

NIR/Raman Spectrometer

February 4, 2014 4:04 pm | Product Releases | Comments

BaySpec Inc. has introduced an all-in-one system combining Raman (532, 785 or 1,064 nm) and NIR absorption/reflection spectroscopy in a single, compact and easy-to-use configuration. The Rayleigh filtering can be turned on and off to switch between Raman and NIR spectral measurements.

LISTED UNDER: Analytical Instrumentation | Raman | Spectrometers

Field-ready Handheld Spectral Analysis Instrument

February 4, 2014 3:52 pm | B&W Tek, Inc. | Product Releases | Comments

The TacticID from B&W Tek is a field-ready handheld spectral analysis instrument designed to enable forensic analysis of unknown chemicals by first responders. The TacticID uses Raman spectroscopy, allowing users to get real-time actionable identification of potential threats and reducing operational uncertainty and response time without compromising the integrity of the sample or chain of evidence.

LISTED UNDER: Analytical Instrumentation | Raman | Spectrometers

Benchtop Mass Spectrometers

February 4, 2014 3:21 pm | Hiden Analytical, Inc. | Product Releases | Comments

Hiden Analytical's QGA systems are benchtop mass spectrometer systems for direct real-time analysis, quantification and control of gas-related processes ranging in pressure from 100 mbar to 50 bar. The spectrometers are coupled to the user process by the integral robust, flexible, quartz-lined heated capillary with sample consumption rates as low as 1 mL/min and response times as low as 150 sec.

LISTED UNDER: Analytical Instrumentation | Other Mass | Spectrometers

Laser Raman Spectrometer

February 4, 2014 3:07 pm | Product Releases | Comments

Building upon the high-performance capabilities of the NRS-5000/7000 Series Raman instruments, JASCO Inc. has introduced a new compact and easy-to-use NRS-4100 Series laser Raman spectrometer. The compact spectrometer measures 24 in tall, 22 in wide and 24 in deep and weighs 120 lbs. The use of a dual-laser system at 532 nm and 785 nm and a spectrograph resolution down to 0.7 cm-1/pixel makes the NRS-4100 suitable for many application in R&D, forensics and quality control.

LISTED UNDER: Analytical Instrumentation | Raman | Spectrometers

Pages

X
You may login with either your assigned username or your e-mail address.
The password field is case sensitive.
Loading