Discovery: Electric charge can change freezing point of water

Posted In: Strange But True | R&D Daily | Electrical Materials | Materials Science | Materials Testing | Thermoelectrics | Material Science

By Lisa Grossman

Monday, February 8, 2010

newsvine diigo google
slashdot
Share
Loading...

A watched pot never boils, but an electrically charged pot sometimes freezes.

A study in the Feb. 5 Science reports that water can freeze at different temperatures depending on whether the surface it rests on is positively or negatively charged. Under certain conditions, water can even freeze as it heats up.

“We are very, very surprised by this result,” says study coauthor Igor Lubomirsky of the Weizmann Institute of Science in Rehovot, Israel. “It means that by controlling surface charge, either positive or negative, you can either suppress ice formation or enhance ice formation.”

Water usually begins freezing by forming an ice crystal around a particle of dust or some other impurity. Without that starting point, water can stay liquid well below its freezing point, down to about -42º Celsius. This supercooled water is useful in nature and in the lab, from frogs and fish surviving long winters to cryogenic preservation of blood and tissues.

Scientists have suspected for decades that electric fields could be used to trigger freezing in supercooled water. A molecule of water has a slight positive charge on one end and a negative charge on the other, so electric fields could snap water molecules into a rigid formation by aligning them according to charge.

But previous experiments to understand whether electric fields can influence freezing were complicated by the materials used. The best materials for holding electric charge are metals, but as anyone who has tried to open a car door after a snowstorm knows, ice forms easily on metals even without a charge.

“If you try to do it with metal, you don’t know what is from the electric field and what is from the metal itself,” Lubomirsky says. “We wanted to know whether it is the charge that does it, or something special in metal.”

Instead of metal, Lubomirsky and his colleagues used a pyroelectric material, which can form a short-lived electric field when heated or cooled. The researchers used four pyroelectric crystals, each of which was placed inside a copper cylinder. The bottom surfaces of two crystals were coated with chromium to conduct an electric charge, and the other two were coated with an aluminum oxide to keep the surface uncharged.

The researchers placed the experimental setup in a humid room and turned down the thermostat until water droplets formed on each crystal, then cooled the room further until the water froze.

With no charge on the surface, the water froze at -12.5º C, on average. But on the positively charged surface, water froze at a relatively balmy -7º. And on a negatively charged surface, ice formed, on average, at a chilly -18º.

Read more of the original article at Science News

Study abstract

 

JOIN THE DISCUSSION
Rate Article:  Average 5 out of 5
Register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

New To Market

more

AFM and spectroscopy combined for physical and life sciences
AFM and spectroscopy combined for physical and life sciences

Veeco Instruments Inc. has designed its new IRIS models for Innova and BioScope Catalyst atomic force microscopes (AFMs) to provide superior integration and accessibility for combined AFM and Raman spectroscopy research.

Lenses optimized for peak SWIR performance

Enhanced 25-mm and 50-mm lenses from Navitar Inc. are specifically designed for short-wavelength infrared (SWIR) cameras. The lenses function in the wavelengths of 500 nm to 1700 nm, with 90% +/- 5% transmission across the range.

Tools & Technology

more

Syringe pump to deliver full stroke
Syringe pump to deliver full stroke

The Legato 270 Syringe Pump has an optimized user configurable syringe mechanism designed to deliver a full volume in infuse and withdraw modes whether using small or large syringes.

Potentiometric titrator can run four stations in parallel(2)

JM Science’s new Potentiometric Titrator (COM-1700) allows up to four different titrations to run in parallel at the same time.

Advertisement

Advertisement